Schneider Electric LMC600CAA10000 - Motion Controller



  • Product Code: LMC600CAA10000
  • Availability: In Stock


Schneider Electric LMC600CAA10000 - Motion Controller
Middle Technical Document | Revision A | Machine Automation Series
1. Product Overview
The Schneider Electric LMC600CAA10000 is a high-performance PAC motion controller, belonging to Lexium 600 series, designed for advanced machine automation and multi-axis servo motion control applications. It integrates PLC logic control and motion control functions in a single unit, supports synchronized multi-axis motion and complex trajectory control with high precision.
This controller is fully compatible with Schneider EcoStruxure Machine Expert software, Modbus TCP/IP and CANopen communication protocols, featured with compact structure, rich I/O interfaces and high-speed pulse output, ideal for packaging, material handling, robotics and metal processing machinery.
2. Core Technical Specifications
Controller Core Specs:
- Main CPU: 32-bit High-performance Processor, 800MHz Clock Speed
- Memory: 512MB RAM, 1GB Flash Memory, Expandable SD Card Slot
- Motion Axis Capacity: Up to 16 Axes, Support Electronic Cam & Gearing
I/O & Communication Interfaces:
- Integrated I/O: 24 Digital Inputs, 16 Digital Outputs, 2 Analog Inputs
- Communication: 2x Ethernet (Modbus TCP/IP), 2x CANopen, RS-485 Serial
- High-speed Pulse Output: 1MHz, Support SSCNET III/H & EtherCAT Protocol
3. Operational Parameters & Environmental Limits
Operating Temperature: 0°C to +60°C (32°F to +140°F)
Storage Temperature: -25°C to +70°C (-13°F to +158°F)
Humidity Tolerance: 5% ~ 95% non-condensing, IP20 Protection Grade
Power Supply: 24 VDC (18 - 30 VDC), Power Consumption ≤ 15W, Redundant Power Supported
Operating Vibration: 5 to 15Hz (0.15mm), 15 to 150Hz (2g), Shock Resistant 15g
4. Installation & Safety Notes
This motion controller is designed for standard 35mm DIN rail mounting in electrical control cabinets with vertical installation recommended for optimal heat dissipation.
All electrical wiring shall comply with IEC 61131-2 and NFPA 79 standards, ensure proper grounding to avoid electromagnetic interference and static damage.
Disconnect all power sources before wiring or maintenance to prevent electric shock hazards and device permanent damage.
Avoid installation in environments with corrosive gas, heavy dust or direct sunlight, regular dust cleaning is recommended for long-term stability.