PTX 59B2-TC-A1-CA-H4-PN Pressure Transmitter
1. Product Overview
The PTX 59B2-TC-A1-CA-H4-PN is a high-precision industrial pressure transmitter designed for harsh process control environments. Engineered with advanced piezoresistive sensing technology, it delivers reliable and accurate pressure measurement for oil & gas, chemical processing, and industrial automation applications.
This model features a rugged stainless steel construction, corrosion-resistant materials, and a hermetically sealed design to ensure long-term stability and performance in extreme operating conditions, including high temperature and vibration environments.
2. Technical Specifications
- Measurement Range: 0-100 bar (configurable up to 500 bar)
- Output Signal: 4-20 mA (2-wire) with HART 7.0 communication
- Accuracy: ±0.075% of full scale (including linearity, hysteresis, repeatability)
- Operating Temperature: -40°C to +125°C (-40°F to +257°F)
- Process Connection: 1/2" NPT male (stainless steel 316L)
- Electrical Connection: Cable gland (PG9) / DIN 43650 A connector
- Pressure Rating: 400% overload protection
- Enclosure Rating: IP67 (NEMA 4X)
- Power Supply: 10.5-45 VDC (loop-powered)
3. Installation Instructions
- Mount the transmitter in a vertical or horizontal orientation, ensuring minimal vibration exposure.
- Clean the process connection port to remove debris before installation.
- Torque the process connection to 55 N·m (40 ft-lb) using a calibrated torque wrench.
- Connect the 2-wire signal cable to the terminal block (polarity-sensitive: +V to positive, -V to negative).
- Seal all cable entry points to maintain IP67 enclosure rating.
- Apply power to the transmitter and verify output signal (4 mA at zero pressure, 20 mA at full scale).
- Calibrate the transmitter using HART communicator if necessary (refer to calibration section).
Important Safety & Maintenance Notes
- Installation and maintenance must be performed by certified personnel only.
- Isolate process pressure and disconnect power before servicing the transmitter.
- Do not exceed the maximum pressure or temperature ratings to prevent sensor damage.
- Perform periodic calibration (every 6-12 months) to maintain accuracy specifications.
- Avoid exposure to corrosive chemicals unless compatible with 316L stainless steel material.
Document Revision: 2.1 | Date: January 2026 | Industrial Process Instruments Division
Model Configuration: TC (Temperature Compensated) | A1 (Analog Output) | CA (Chemical Resistant) | H4 (High Temp) | PN (NPT Connection)